 Current Transducer HTFS 200..800-P IPN = 200 - 400 - 800 A
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
All Data are given with a R L = 10 k
Electrical data
Primary nominal r.m.s. current IPN (A)IP (A) 200 400 800 Primary current measuring range 300 600 1200 Type
Features
HTFS 200-P HTFS 400-P HTFS 800-P
* Hall effect measuring principle * Galvanic isolation between primary * Low power consumption * Single power supply +5V * Ratiometric offset * TA = -40..+105 C * Fixation by M3 nuts and screws
and secondary circuit
VOUT VREF
RL k ROUT CL VC IC
Analog output voltage @ IP VREF (1.25*IP/IPN) V IP = 0 VREF 0.025 V Internal Reference1) - Output voltage 1/2VC 0.025 V VREF Output impedance typ. 200 VREF Load impedance 200 k Output load resistance 2 Output impedance Max. output capacitive load Supply voltage ( 5 %) Current consumption @ VC = 5 V < 10 <1 5 22 F V mA
Advantages
* Small size and space saving * Only one design for wide current * High immunity to external
ratings range interference.
Accuracy - Dynamic performance data
X
L
TCVOUT TCVREF TCVOUT / VREF TC G VOM t ra tr di/dt
f
Accuracy 2) @ IPN , TA = 25C Linearity error 0 .. 1.5 x IPN Thermal drift of VOUT @ IP = 0 Thermal drift of VREF Thermal drift of VOUT / VREF @ IP = 0 Thermal drift of the gain Residual voltage @ IP = 0, after an overload of 3 x IPN DC Reaction time @ 10 % of IPN Response time @ 90 % of IPN di/dt accurately followed Output noise (DC ..10 kHz) (DC .. 1 MHz) Frequency bandwidth (- 3 dB) 3)

1 0.5 0.3 0.01 0.2
% of IPN % of IPN mV/K %/K mV/K
* VREF. IN/OUT
Applications
* Forklift drives * AC variable speed drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies * Switched Mode Power Supplies * Power supplies for welding
applications. (SMPS) (UPS)
0.05% of reading/K
< 0.5 <3 <7 > 100 < 15 < 40 DC .. 20
% of IPN s s A/s mVpp mVpp kHz
General data
TA TS m Ambient operating temperature Ambient storage temperature UL94 classification Mass Standards - 40 .. + 105 C - 40 .. + 105 C V0 60 g EN 50178: 1997
Application Domain
* Industrial
Notes : 1) It is possible to overdrive VREF with an external reference voltage between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA. 2) Excluding offset. 3) Small signal only to avoid excessive heatings of the magnetic core.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
051110/3
Page 1/3
LEM
www.lem.com
Current Transducer HTFS 200..800-P
Isolation characteristics
Vb Nominal Voltage with IEC 61010-1 standards and following conditions - Single insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field Nominal Voltage with EN 50178 standards and following conditions - Reinforced insulation - Over voltage category III - Pollution degree 2 - Heterogeneous field R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn R.m.s. voltage for partial discharge extinction @ 10pC Impulse withstand voltage 1.2/50s Creepage distance Clearance distance Comparative tracking index (Group IIIa) 150 V r.m.s.
Vb
150
V r.m.s.
Vd Ve Vw dCp dCl CTI
2.5 >1 4 >4 >4 > 220
kV kV kV mm mm V
If insulated cable is used for the primary circuit, the voltage category could be improved with the following table : Cable insulation (primary) Category HAR 03 300V CAT III HAR 05 400V CAT III HAR 07 500V CAT III
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
051110/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3
LEM
www.lem.com
Dimensions HTFS 200..800-P (in mm. 1 mm = 0.0394 inch)
Ip
0.5 d6 d5 16.5 1 4-d3.5 40 33
5 16 26 3-P=2.54 4-0.25x0.5 3.5+/-1 7 4.5
4 1
Terminal Pin
Required Connection Circuit
HTFS 4 VRef
1...+5V 2...0V 3...Output 4...Vref (IN/OUT) Vref (IN/OUT)
3 Output 2 0V 47nF 47nF 4.7nF
Output 0V +5V
1 +5V
Operation Principle
+Vc Vout Vref.(IN/OUT) Ip 0V
Mechanical characteristics
* * * *
General tolerance Fixation by Recommended fastening torque Fastening & connection of secondary Recommended PCB hole 0.2 mm 4 x M3 (not supplied) < 2.5 Nm 4 pins 0.5 x 0.25 O 0.7 mm
Remarks
* VOUT is positive when IP flows in the direction of the
arrow.
* Temperature of the primary conductor should not
exceed 120C.
33
d22
20
051110/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 3/3
LEM
www.lem.com


▲Up To Search▲   

 
Price & Availability of HTFS200-P05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X